Custom Query (3351 matches)

Filters
 
Or
 
  
 
Columns

Show under each result:


Results (52 - 54 of 3351)

Ticket Resolution Summary Owner Reporter
#2620 fixed vn10.9 AMIP run PI control um_support admg26
Description

Hello,

Monsoon user: almin Archive: /crum/ UM-UKCA vn10.9 Trunk AMIP run using 1850 PI control CMIP6 emission files and start dumps.

Suite: u-ax344

Run crashes after 12 years with the following

????????????????????????????????????????????????????????????????????????????????
???!!!???!!!???!!!???!!!???!!!       ERROR        ???!!!???!!!???!!!???!!!???!!!
?  Error code: 100
?  Error from routine: set_thermodynamic
?  Error message: A total of     3 points had negative mass in set_thermodynamic. This indicates the pressure fields are inconsistent between different levels and the model is about to fail.
?  Error from processor: 158
?  Error number: 38
????????????????????????????????????????????????????????????????????????????????

I am confused as to why it ran for so long before falling over.

Cheers, Alison

#1982 fixed vn10.4 Rose suite on ARCHER: tasks are only ready or waiting um_support luke
Description

Hello,

I am attempting to run a vn10.4 GA7+StratTrop Rose suite on ARCHER (u-ag308). The tasks never run on the HPC though, they are just listed as ready or waiting.

I have attached a screenshot showing the state of the suite.

Am I doing something silly, or do I need to change something to get it to run?

Many thanks, Luke

#1507 answered vn 8.6 no CRUN/NRUN option available ros markr
Description

Hello, I do not understand why the NRUN and CRUN buttons do not work in vn8.6 (my case is xklsf) which I want to run for 16 months simulation.

Compile and Run > Compile and Run options for Atmosphere and Reconfiguration

Note: See TracQuery for help on using queries.