Opened 4 years ago

Closed 4 years ago

#1623 closed help (answered)

Routine generating error: UKCA_FLUPJ

Reported by: dh023729 Owned by:
Component: UKCA Keywords:
Cc: Platform:
UM Version: 6.6.3

Description (last modified by ros)

Hi,

In a HadGEM2 run, I did a sensitivity experiment by changing SST and Sea Ice. The model crushed within the first month, with following error. The model includes the UKCA tropospheric chemistry, and the error indicated that it was a issue of UKCA.

Is this a known issue that UKCA is sensitive to SST/Sea Ice changes?

Thanks,
Liang

*********************************************************************************
 UM ERROR (Model aborting) :
 Routine generating error: UKCA_FLUPJ
 Error code:  123
 Error message:
Value of x not within range of xs
 *********************************************************************************

Change History (3)

comment:1 Changed 4 years ago by dh023729

Hi,

After further test, by far, I can say that it is Sea Ice causing the problem.

Both SST and Sea Ice ancillaries are generated using *xancil* with option of AMIP II format. This matches job configuration in UMUI which is using AMIP II method to update SST and Sea Ice.

I wonder that is this due to wrong format of ancillaries or due to the abnormal value in the ancillaries?

The job id is xlpgg.

Many thanks,
Liang

comment:2 Changed 4 years ago by grenville

Hi Liang

Charlie Williams has done lots of runs with SST and Sea ice ancillaries which he generated. Can you check with Charlie?

Grenville

comment:3 Changed 4 years ago by ros

  • Description modified (diff)
  • Resolution set to answered
  • Status changed from new to closed

No further response was made to this ticket so it is now being closed. Please contact the helpdesk if you still require any help.