Description

If you see this error on ARCHER — in this case from a UM 8.6 reconfiguration job

Wed Sep 2 14:59:04 2015: [unset]:_pmi_daemon_barrier:daemon pipe read failed from PE 0 errno = Success
Wed Sep 2 14:59:04 2015: [unset]:_pmiu_daemon:_pmi_daemon_barrier failed
[NID 00021] 2015-09-02 14:59:04 Apid 17258110: initiated application termination

One possible cause is that the executable trying to run was linked with -lm -lc — relink with these flags removed.

Grenville

Change History (4)

comment:1 Changed 2 years ago by grenville

  • Resolution set to fixed
  • Status changed from new to closed

comment:2 Changed 16 months ago by pmcjs

Hi Grenville,

I have encountered very similar errors in my ARCHER jobs in version 6.6.3. I can't seem to find anything in the UMUI where I can modify this option - please could you explain how?

Thanks,
Chris

comment:3 Changed 16 months ago by pmcjs

  • Resolution fixed deleted
  • Status changed from closed to reopened

comment:4 Changed 8 weeks ago by willie