Description

Hello,

I'm getting an error when running my job xlkes, it says the compiler can't find MPL (and hence gives various errors when bits of code try to use MPL). See attached .comp.leave file (/home/n02/n02/mnewland/output/xlkes000.xlkes.d16049.t101455.comp.leave).

Do you know why this is?

Thanks!

Attachments (1)

xlkes000.xlkes.d16049.t101455.comp.leave (221.2 KB) - added by MikeN 3 years ago.

Download all attachments as: .zip

Change History (4)

Changed 3 years ago by MikeN

comment:1 Changed 3 years ago by annette

Hi Mike,

You have some HECToR-specific settings in this job that mean the correct libraries are not being picked up. In the UMUI go to Compilation and Modifications → UM user override files and change to the following:

  • /home/umui/overrides/archer_cce_7.3_file
  • /home/umui/overrides/archer_cce_7.3_machine

The other file (hector_cce_7.3_asad_chem_diags) looks OK.

You should probably also update the version of the vn7.3 ncas branch so you are picking up the latest changes. Go to FCM Configuration → FCM Options for Atmosphere and Reconfiguration. Then next to fcm:um_br/pkg/Config/VN7.3_ncas/src leave the version number blank.

Also ARCHER has 24 cores per node so it is best to run on a number of processors which is a multiple of 24. To change this go to: User information and target machine → Target Machine.

Annette

comment:2 Changed 3 years ago by annette

  • Owner changed from um_support to annette
  • Status changed from new to assigned

comment:3 Changed 3 years ago by ros

  • Resolution set to answered
  • Status changed from assigned to closed

No further activity on this ticket so now being closed.