how can I force a suite-shutdown on puma?

Reported by: marcus Owned by: ros
Component: UM Model Keywords: shutdown cylc
Cc: Platform: ARCHER
UM Version: 10.4

Description

Hi, I am trying to force the shutdown of a running suite (u-ag541).

On MONSooN I can directly kill the process by logging into exvmscylc however I don't know what to do when running on ARCHER.

There is no instance of my model experiment in the ARCHER queue. I've tried "rose suite-shutdown" and "cylc shutdown —now u-ag541" on Puma without any success.

What else could I do?

Many thanks,
Marcus

Change History (3)

comment:1 Changed 3 years ago by ros

  • Owner changed from um_support to ros
  • Status changed from new to accepted

Hi Marcus,

If you can't shutdown the suite through the Cylc GUI or on the command line you can do the same as you have on exvmscylc but on PUMA. The cylc process runs on PUMA so do:

puma$ ps -flu <username> | grep <suitename>

Kill the processes. Note you may also need to remove the associated port file for the suite under ~/.cylc/ports

Regards,
Ros.

comment:2 Changed 3 years ago by marcus

Many thanks, that's great and it helped.
I will close the ticket.

Best regards,
Marcus

comment:3 Changed 3 years ago by marcus

  • Resolution set to fixed
  • Status changed from accepted to closed