Hi helpdesk,

I have the following diagnostics loaded (job ID: xmzbn);

section 0 item 408 - pressure at theta levels after TS (TDAYM, DIAG, UPA)

section 2 item 4 - temperature on theta levsl (TDAYM, DIAG, UPG)

I also have both diagnostic in the climate meaning profile (TDMPMN).

In my output, temperature on theta levels is not included at all. Not just that the the data is empty (NaNs?) but the field does not exist. However, pressure on theta levels does exist.

I searched through the .leave file for 'temperature on theta levels but couldn't find it'. Any thoughts as to why this is happening?

Regards,

Jamie

Change History (2)

comment:1 Changed 10 months ago by annette

  • Keywords stash added
  • Owner changed from um_support to annette
  • Status changed from new to assigned

Hi Jamie,

Do you mean "TEMPERATURE ON THETA LEVELS", Section 16, Item 4? I can see you have this included in your STASH.

There is a warning in the leave file about this diagnostic, but it is well-hidden! If you search for the string "PRELIM" you will find a series of messages from the STASH system that include your new STASH entries (included below).

So I think the problem is using the DIAG domain profile with these fields. I think maybe DALLTH would work, but I'm not sure which levels you wanted to output, so you may need to try one of the other profiles or define your own.

Annette

????????????????????????????????????????????????????????????????????????????????
??????????????????????????????????? WARNING ????????????????????????????????????
? Warning in routine: PRELIM
? Warning Code:   -60
? Warning Message:  DIAGNOSTIC HAS TOP/BOT LEVELS INCONSISTENT; DIAG IGNORED (M,S,I)  1,  0,  4
? Warning generated from processor:     0
????????????????????????????????????????????????????????????????????????????????


????????????????????????????????????????????????????????????????????????????????
??????????????????????????????????? WARNING ????????????????????????????????????
? Warning in routine: PRELIM
? Warning Code:   -40
? Warning Message:  DIAGNOSTIC HAS LEVEL RANGE OUT OF BOUNDS; CORRECTED (M,S,I)  1,  0,  4
? Warning generated from processor:     0
????????????????????????????????????????????????????????????????????????????????


????????????????????????????????????????????????????????????????????????????????
??????????????????????????????????? WARNING ????????????????????????????????????
? Warning in routine: PRELIM
? Warning Code:   -60
? Warning Message:  DIAGNOSTIC HAS TOP/BOT LEVELS INCONSISTENT; DIAG IGNORED (M,S,I)  1,  0,  4
? Warning generated from processor:     0
????????????????????????????????????????????????????????????????????????????????


????????????????????????????????????????????????????????????????????????????????
??????????????????????????????????? WARNING ????????????????????????????????????
? Warning in routine: PRELIM
? Warning Code:   -60
? Warning Message:  DIAGNOSTIC HAS TOP/BOT LEVELS INCONSISTENT; DIAG IGNORED (M,S,I)  1,  16,  4
? Warning generated from processor:     0
????????????????????????????????????????????????????????????????????????????????


????????????????????????????????????????????????????????????????????????????????
??????????????????????????????????? WARNING ????????????????????????????????????
? Warning in routine: PRELIM
? Warning Code:   -40
? Warning Message:  DIAGNOSTIC HAS LEVEL RANGE OUT OF BOUNDS; CORRECTED (M,S,I)  1,  16,  4
? Warning generated from processor:     0
????????????????????????????????????????????????????????????????????????????????


????????????????????????????????????????????????????????????????????????????????
??????????????????????????????????? WARNING ????????????????????????????????????
? Warning in routine: PRELIM
? Warning Code:   -60
? Warning Message:  DIAGNOSTIC HAS TOP/BOT LEVELS INCONSISTENT; DIAG IGNORED (M,S,I)  1,  16,  4
? Warning generated from processor:     0
????????????????????????????????????????????????????????????????????????????????

comment:2 Changed 4 months ago by grenville

  • Resolution set to answered
  • Status changed from assigned to closed