Hello,

I am trying to set a run where I nudge only the winds U/V, and not the temperature. I tried to simply put 0 in the nudging factor of the temperature, but it doesnt seem to work.

I tried to use the FCM branch fcm:um_br/dev/dan2012/vn8.4_Nudge_Temp_Zero/src but it makes the compilation crash (probably because I use version 8.5 and the fcm is for 8.4)

Is there any way to do that? (I could specify a very small nudging factor for the temperature, but I would prefer something more "clean" )

Nicolas

Change History (2)

comment:1 Changed 2 years ago by willie

Hi Nicolas,

If this is xnbrd, then the revision you specified for the nudge branch doesn't exist. Just delete the revision number and try the build again.

Regards
Willie

comment:2 Changed 23 months ago by willie