Description

Hello Helpdesk,

I'm running Stu Webster's nested suite, but the reconfiguration of the N512 driving model is failing with the error

lib-4205 : UNRECOVERABLE library error

The program was unable to request more memory space.

The job ID is u-bp285. The reconfiguration works for 20110127T1200 and 20110127T1200, but fails for 20110128T0000.

I've followed the advice of tickets #1937 and #2570 to allow more memory, but it is still failing for 20110128T0000. I also tried running rose suite-run —new, but the failure persisted.

Are you able to please advise?

Thanks,

Andrew

Change History (3)

comment:1 Changed 11 days ago by grenville

Hi Andrew

Sorry for the slow reply - is this still a problem?

Grenville

comment:2 Changed 11 days ago by anmcr

Hi Grenville,

Yes, if you could please take a look I would be very grateful.

Many thanks,

Andrew

comment:3 Changed 11 days ago by grenville

Andrew

I can only suggest that /home/d01/amworr/cylc-run/u-bp285/share/cycle/20110128T0000Z/glm/ics/glm_atmanl is corrupt - can you make it again?

Grenville