Description

Hi,

My reconfiguration failed with the error

'REPLANCA: PP headers on ancillary file do not match'

followed by

'STASH code in dataset 24 STASH code requested 31'.

The two stash codes refer to sea surface temperature and seaice, which are both ancillaries which I modified. However, I've modifed these often in the past and never had this failure. I've had a look myself but couldn't sort it out.

I'd be grateful for any help.

The job id is 'xfbsf'.

Thanks,

Andrew

Change History (5)

comment:1 Changed 10 years ago by willie

  • Owner changed from um_support to willie
  • Status changed from new to assigned

Hi Andrew,

You should check that the correct ancillary file is used for the sea ice field. You have asked for these fields to be updated daily, but the second time step in the ancillary file is 24/1/2005, the first being 24/7/2004. This is not important since the run is so short, but would need to be cirrecte for longer runs.

Regards,

Willie

comment:2 Changed 10 years ago by jeff

Just to be clear, you have used the sst file in the sea-ice umui panel, you need to change this.

Jeff.

comment:3 Changed 10 years ago by anmcr

Dear Willie and Jeff,

Thanks for looking at this. The job is running now. I do try to filter out stupid errors such as this myself.

Andrew

comment:4 Changed 10 years ago by willie

  • Status changed from assigned to accepted

comment:5 Changed 10 years ago by willie

  • Resolution set to fixed