Opened 10 years ago

Closed 9 years ago

#572 closed help (fixed)

Error Code : 2 Message : READDUMP: BAD BUFFIN OF DATA

Reported by: salvatore Owned by: um_support
Component: UM Model Keywords:
Cc: Platform:
UM Version: 4.5

Description

Hi,
my job xexid suddednly stopped abd when I tried to resubmit it without processing the run fail and in the .leave file I get the following error message:

Error Code : 2

Message : READDUMP: BAD BUFFIN OF DATA

What does it mean? What can I do to continue to make the jon run??

Thanks
Salvatore

Change History (2)

comment:1 Changed 10 years ago by grenville

Salvatore

You need to find out why your job failed. In the leave file xexid000.xexid.d11027.t100611.leave there is the following (and more)

ATMOS TIMESTEP 2838312

FINAL TOTAL ENERGY = NaN J/
INITIAL TOTAL ENERGY = 0.12052E+27 J/
CHG IN TOTAL ENERGY OVER DAY = NaN J/
FLUXES INTO ATM OVER DAY = NaN J/
ERROR IN ENERGY BUDGET = NaN J/
TEMP CORRECTION OVER DAY = NaN K
TEMPERATURE CORRECTION RATE = NaN K/S
FLUX CORRECTION (ATM) = NaN W/M2
FINAL ATM MASS = NaN KG
INITIAL ATM MASS = 0.44850E+21 KG
CORRECTION FACTOR FOR PSTAR = NaN


so the job failed at timestep 2838312; there is little hope of continuing this run as is.

Grenville

comment:2 Changed 9 years ago by willie

  • Resolution set to fixed
  • Status changed from new to closed
Note: See TracTickets for help on using tickets.