Description

Hello Helpdesk,

I'm getting an error message on UMUI for my job xgtec when I close the 'User-STASHmaster files. Diags Progs & Ancills' page. It is repeated for 7 variables in the user stash epflux606 file.

I've looked at similar Hadgem 2 jobs from other users and all give me the same message. The problem is referred to in 2 previous tickets (#546 and #771) but I can't find the solution.

Can you help? Thank you.

Lawrence Jackson

Change History (6)

comment:1 Changed 9 years ago by grenville

  • Owner changed from um_support to grenville
  • Status changed from new to assigned

Lawrence

The UMUI is complaining that the grid (atmospheric zonal uv points) for stash items 30 310-316 isn't supported. These diagnostics are output monthly as monthly means. Has your model run for one month - were the diagnostics output? The UMUI error doesn't prevent the model from running, so I can only suggest running the model and checking the output.

Grenville

comment:2 Changed 9 years ago by eelsj

Grenville,

The job currently fails to run so I can't see if the diagnostics are output. I get an error message at the start of the run (after successful compilation):

sys-2 : UNRECOVERABLE error on system request

No such file or directory

Encountered during an OPEN of unit 56
Fortran unit 56 is not connected

This message is repeated 96 times. Coincidently I am using 12 (East-West) and 8 (North-South) processors. I'm currently trying a run with the number of processors switched round (XGTEB).

This problem was also raised on ticket #771 but I can't see a solution.

I would appreciate any help you could provide. Thank you.

Lawrence Jackson

comment:3 Changed 9 years ago by grenville

Lawrence

It is complaining that it can't find the file to open on unit 56. This file is $HG2CCL60_ancils/volcts_sato02e.dat. As far as I can see $HG2CCL60_ancils is defined as /work/n02/n02/hum/hg6.6.3/HG2CCL60_ancils, but that directory does not contain the file volcts_sato02e.dat which is consistent with the error message. This file is set in the Natural Climate Forcing section of Climatologies.

Grenville

comment:4 Changed 9 years ago by grenville

Lawrence

Such a file exists in /work/n02/n02/hum/hg6.6.3/HG2CCL60_ancils/HG2AMIP_ancils/volcts_sato02e.dat

Grenville

comment:5 Changed 9 years ago by eelsj

Grenville

Thank you. Problem solved.

Lawrence

comment:6 Changed 9 years ago by grenville

  • Resolution set to fixed
  • Status changed from assigned to closed