Opened 8 years ago
Closed 7 years ago
#850 closed help (fixed)
Problem running old (Phase 2a or possibly even Phase 1) idealised job
Reported by: | laurahb | Owned by: | willie |
---|---|---|---|
Component: | HECToR | Keywords: | |
Cc: | Platform: | ||
UM Version: | 6.1 |
Description
I am trying to run the job xfffc on Phase 3. This previously ran ok but is having problems now after the upgrade to Phase 3. I have set it to recompile, but it's still falling over.
My most recent output file is
/home/n02/n02/laurahb/um/umui_out/xfffc000.xfffc.d12142.t163131.workstat
Change History (3)
comment:1 Changed 8 years ago by willie
- Owner changed from um_support to willie
- Status changed from new to accepted
comment:2 Changed 8 years ago by willie
Laura wrote
I think the "cannot set option" error was to do with missing one of the mods you said since it stopped happening when I added the hector_io one. I had done all the setup stuff on the cms pages so that's definitely ok. I made a copy of the job (xfffm) in case somehow the problem was sticking around when I re-ran it, but it's still not working. I'm now getting different errors though:
UM ERROR (Model aborting) :
Routine generating error: INITIAL
Error code: 4
Error message:
PR_INHDA: Consistency check
Any ideas what this means?
It looks like you now need to switch reconfiguration on. Don't forget to switch on the pum_full_6.1.mf77 mod set for the reconfiguration.
Regards,
Willie
comment:3 Changed 7 years ago by willie
- Resolution set to fixed
- Status changed from accepted to closed
Hi Laura,
Please make sure that you have followed the instructions at http://cms.ncas.ac.uk/index.php/component/content/1583?task=view. Your .profile needs to have TARGET_MC=cce. I think the jobs should have the modsets hector_io.mf77 and pum_full_6.1.mf77 switched on.
I haven't seen the "cannot set option" error before, but I suspect it is due to the setup.
Regards,
Willie