Opened 7 years ago

Closed 7 years ago

#884 closed help (fixed)

error in reconfiguration

Reported by: anmcr Owned by: um_support
Component: UM Model Keywords:
Cc: Platform:
UM Version: 7.6

Description

Hello,

I have a job xhldc which has a problem with the reconfiguration. I have copied the error below. It is obviously probably due to the number of vertical levels in the parameter 'decoupled screen temp on tiles' which has 1 level in the startdump. But I am afraid I do not know how to remedy this.

Thanks,

Andrew

The error is


Interpolating Field 79 ( Section 0 ) ( Stashcode 490 ) DECOUPLED SCREEN TEMP ON TILES K

ERROR!!! in reconfiuration in routinr Rcf_vertical
Error Code:- 10
Error Message:- No interpoaltion, but data field sizes/levels are different!
Error generated from processor 0

Change History (3)

comment:1 Changed 7 years ago by grenville

Andrew

Please switch off the hand edit ~willie/hand_edits/RECONA_add_srce_4.txt and add the hand edit ~grenville/hand_edits/handedit_1to9tiles.

Doing this results is the reconfiguration succeeding, but I haven't tried running the job.

Grenville

comment:2 Changed 7 years ago by anmcr

Dear Grenville,

Thank you for this. The job successfully reconfigured and is now running.

Andrew

comment:3 Changed 7 years ago by grenville

  • Resolution set to fixed
  • Status changed from new to closed
Note: See TracTickets for help on using tickets.