Opened 9 years ago
Closed 9 years ago
#884 closed help (fixed)
error in reconfiguration
Reported by: | anmcr | Owned by: | um_support |
---|---|---|---|
Component: | UM Model | Keywords: | |
Cc: | Platform: | ||
UM Version: | 7.6 |
Description
Hello,
I have a job xhldc which has a problem with the reconfiguration. I have copied the error below. It is obviously probably due to the number of vertical levels in the parameter 'decoupled screen temp on tiles' which has 1 level in the startdump. But I am afraid I do not know how to remedy this.
Thanks,
Andrew
The error is
Interpolating Field 79 ( Section 0 ) ( Stashcode 490 ) DECOUPLED SCREEN TEMP ON TILES K
ERROR!!! in reconfiuration in routinr Rcf_vertical
Error Code:- 10
Error Message:- No interpoaltion, but data field sizes/levels are different!
Error generated from processor 0
Change History (3)
comment:1 Changed 9 years ago by grenville
comment:2 Changed 9 years ago by anmcr
Dear Grenville,
Thank you for this. The job successfully reconfigured and is now running.
Andrew
comment:3 Changed 9 years ago by grenville
- Resolution set to fixed
- Status changed from new to closed
Andrew
Please switch off the hand edit ~willie/hand_edits/RECONA_add_srce_4.txt and add the hand edit ~grenville/hand_edits/handedit_1to9tiles.
Doing this results is the reconfiguration succeeding, but I haven't tried running the job.
Grenville