Opened 7 years ago

Closed 7 years ago

#912 closed help (fixed)

PS22 global run fails

Reported by: anmcr Owned by: um_support
Component: UM Model Keywords:
Cc: Platform:
UM Version: 7.3

Description

Hi Willie,

I am trying to run a job (xhldh) which is a 'PS22 Global run' vn 7.3.

I previously got this to run successfully. However, the model is now failing when I begin from a different initilisation time. The error is


UM ERROR (Model aborting) :
Routine generating error: UM_SETUP
Error code: 2
Error message:
READHIST: Read ERROR on history file for namelist NLCFILES

I am afraid that I have never come across this error before. So I would really appreciate your help.

Thanks,

Andrew

Change History (3)

comment:1 Changed 7 years ago by willie

Hi Andrew,

I rebuilt the executables and it seems to be working fine.

Regards,

Willie

comment:2 Changed 7 years ago by anmcr

Thanks Willie.

Please close this ticket.

Andrew

comment:3 Changed 7 years ago by willie

  • Resolution set to fixed
  • Status changed from new to closed
Note: See TracTickets for help on using tickets.